6 resultados para STRATIFICATION

em Dalarna University College Electronic Archive


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report describes the work done creating a computer model of a kombi tank from Consolar. The model was created with Presim/Trnsys and Fittrn and DF were used to identify the parameters. Measurements were carried out and were used to identify the values of the parameters in the model. The identifications were first done for every circuit separately. After that, all parameters are normally identified together using all the measurements. Finally the model should be compared with other measurements, preferable realistic ones. The two last steps have not yet been carried out, because of problems finding a good model for the domestic hot water circuit.The model of the domestic hot water circuit give relatively good results for low flows at 5 l/min, but is not good for higher flows. In the report suggestions for improving the model are given. However, there was not enough time to test this within the project as much time was spent trying to solve problems with the model crashing. Suggestions for improving the model for the domestic circuit are given in chapter 4.4. The improved equations that are to be used in the improved model are given by equation 4.18, 4.19 and 4.22.Also for the boiler circuit and the solar circuit there are improvements that can be done. The model presented here has a few shortcomings, but with some extra work, an improved model can be created. In the attachment (Bilaga 1) is a description of the used model and all the identified parameters.A qualitative assessment of the store was also performed based on the measurements and the modelling carried out. The following summary of this can be given: Hot Water PreparationThe principle for controlling the flow on the primary side seems to work well in order to achieve good stratification. Temperatures in the bottom of the store after a short use of hot water, at a coldwater temperature of 12°C, was around 28-30°C. This was almost independent of the temperature in the store and the DHW-flow.The measured UA-values of the heat exchangers are not very reliable, but indicates that the heat transfer rates are much better than for the Conus 500, and in the same range as for other stores tested at SERC.The function of the mixing valve is not perfect (see diagram 4.3, where Tout1 is the outlet hot water temperature, and Tdhwo and Tdhw1 is the inlet temperature to the hot and cold side of the valve respectively). The outlet temperature varies a lot with different temperatures in the storage and is going down from 61°C to 47°C before the cold port is fully closed. This gives a problem to find a suitable temperature setting and gives also a risk that the auxiliary heating is increased instead of the set temperature of the valve, when the hot water temperature is to low.Collector circuitThe UA-value of the collector heat exchanger is much higher than the value for Conus 500, and in the same range as the heat exchangers in other stores tested at SERC.Boiler circuitThe valve in the boiler circuit is used to supply water from the boiler at two different heights, depending on the temperature of the water. At temperatures from the boiler above 58.2°C, all the water is injected to the upper inlet. At temperatures below 53.9°C all the water is injected to the lower inlet. At 56°C the water flow is equally divided between the two inlets. Detailed studies of the behaviour at the upper inlet shows that better accuracy of the model would have been achieved using three double ports in the model instead of two. The shape of the upper inlet makes turbulence, that could be modelled using two different inlets. Heat lossesThe heat losses per m3 are much smaller for the Solus 1050, than for the Conus 500 Storage. However, they are higher than those for some good stores tested at SERC. The pipes that are penetrating the insulation give air leakage and cold bridges, which could be a major part of the losses from the storage. The identified losses from the bottom of the storage are exceptionally high, but have less importance for the heat losses, due to the lower temperatures in the bottom. High losses from the bottom can be caused by air leakage through the insulation at the pipe connections of the storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Participation as observer at the meeting of Task 14 of IEA's Solar Heating and Cooling Projects held in Hameln, Germany has led to greater understanding of interesting developments underway in several countries. This will be of use during the development of small scale systems suitable for Swedish conditions. A summary of the work carried out by the working groups within Task 14 is given, with emphasis on the Domestic Hot Water group. Experiences of low-flow systems from several countries are related, and the conclusion is drawn that the maximum theoretical possible increase in performance of 20% has not been achieved due to poor heat exchangers and poor stratification in the storage tanks. Positive developments in connecting tubes and pumps is noted. Further participation as observer in Task 14 meetings is desired, and is looked on favourably by the members of the group. Another conclusion is that SERC should carry on with work on Swedish storage tanks, with emphasis on better stratification and heat exchangers, and possible modelling of system components. Finally a German Do-it-Vourself kit is described and judged in comparison with prefabricated models and Swedish Do-it-Yourself kits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thesis belongs to the field of lexical semantics studies, associated with describing the Russian linguistic world-image. The research focuses on the universal situation of purchase and sale as reflected in the Russian lexical standard and sub-standard. The work deals also with subjects related to the sphere of social linguistics: the social stratification of the language, the structure of sub-standard, etc. The thesis is a contribution to the description of the Russian linguistic world-image as well as to the further elaboration of the conceptional analysis method. The results are applicable in teaching Russian as a foreign language, particularly in lexis and Russian culture and mentality studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Genre stratification and the mass media’s neutralization of the critique of ADHD: A sociology of knowledge perspective This study examines how the Swedish mass media has dealt with the opposition against the neuropsychiatric diagnosis ADHD (Attention Deficit Hyperactivity Disorder). Drawing on empirical data from eight of the largest newspapers in Sweden (n=778 articles) the study focuses on the scientific controversy of DAMP, 2000–2006. DAMP (Dysfunction in Attention, Motor Control and Perception) is a diagnostic term denoting difficulties similar to ADHD, and which was used in Sweden at the time of the controversy. The study uncovers the ideological role played by the mass media during the DAMP-controversy, and demonstrates the significance of genre. While the spokespersons for DAMP/ADHD were given exclusive and systematic access to the news genre, the forum of fact-production in the mass media, the critics of DAMP/ADHD were confined to arguing and expressing their opinions in the debate genre. Based on the various effects of genre differences a comprehensive analytical tool for the sociology of knowledge, called genre stratification, is developed in the study 

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The importance of investigating cost reduction in materials and components for solar thermal systems is crucial at the present time. This work focuses on the influence of two different heat exchangers on the performance of a solar thermal system. Both heat exchangers studied are immersed helically coiled, one made with corrugated stainless steel tube, and the other made with finned copper tube with smooth inner surface.A test apparatus has been designed and a simple test procedure applied in order to study heat transfer characteristics and pressure drop of both coils. Thereafter, the resulting experimental data was used to perform a parameter identification of the heat exchangers, in order to obtain a TRNSYS model with its corresponding numerical expression. Also a representative small-scale combisystem model was designed in TRNSYS, in order to study the influence of both heat exchangers on the solar fraction of the system, when working at different flow rates.It has been found that the highest solar fraction is given by the corrugated stainless steel coil, when it works at the lowest flow rate (100 l/hr). For any higher flow rate, the studied copper coil presents a higher solar fraction. The advantageous low flow performance of stainless steel heat exchanger turns out to be beneficial for the particular case of solar thermal systems, where it is well known that low flow collector loops lead to enhanced store stratification, and consequently higher solar fractions.Finally, an optimization of the stainless steel heat exchanger length is carried out, according to economic figures. For the given combisystem model and boundary conditions, the optimum length value is found between 10 and 12 m.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New opportunities for social stratification research in Sweden: International occupational classifications and stratification measures over time The Swedish occupational classifications have in recent years been changed to a version of the international standard ISCO-88(COM), i.e. SSYK 96. As a consequence, a wide variety of internationally well-known stratification measures can be applied to Swedish data sets. In this article some tests of the validity of translation keys between the older national classifications and SSYK 96 are presented. The keys seem to work satisfactorily. Thus, it is possible to create long time-series with ISCO/SSYK and use these well-known stratification measures over time. Hence, the international interest in Swedish data sets, and empirical results based on these data sets, could rise. Moreover, in the article an empirical regularity, which is quite astonishing, is paid attention to; stratification measures based on different theoretical rationales indicate very similar hierarchies of occupations.